ABB分析儀電導(dǎo)率探頭2221,2241,2271
  • ABB分析儀電導(dǎo)率探頭2221,2241,2271
掃一掃

掃一掃
進(jìn)入手機(jī)店鋪

ABB分析儀電導(dǎo)率探頭2221,2241,2271

產(chǎn)品價(jià)格:
電議
產(chǎn)品型號(hào):
2221,2241,2271
供應(yīng)商等級(jí):
企業(yè)未認(rèn)證
經(jīng)營模式:
工廠
企業(yè)名稱:
廣州宇林自動(dòng)化控制設(shè)備有限公司
所屬地區(qū):
發(fā)布時(shí)間:
2013/1/18 15:54:14

86-020-38897067       13360550980

林立(聯(lián)系我時(shí),請(qǐng)說明是在維庫儀器儀表網(wǎng)看到的,謝謝)

企業(yè)檔案

廣州宇林自動(dòng)化控制設(shè)備有限公司

企業(yè)未認(rèn)證營業(yè)執(zhí)照未上傳

經(jīng)營模式:工廠

主營產(chǎn)品:無線控制系統(tǒng),智能計(jì)數(shù)器,水泥袋計(jì)數(shù)器,傳感器,料位開關(guān),電磁閥,IWAKI泵,高溫鏡頭,無線數(shù)傳模塊

產(chǎn)品搜索

手機(jī)訪問

掃一掃
進(jìn)入手機(jī)店鋪

產(chǎn)品品牌:
ABB
產(chǎn)品型號(hào):
2221,2241,2271

Conductivity Cell 2221

The Conductivity Cell 2221 is a dip-type cell designed for immersion in open channels and tanks in paper & pulp manufacture, industrial effluent, water quality monitoring in tidal rivers, river & canal waters, brewing & dairy CIP plants and desalination plants.The associated conductivity instrument utilizes a 2221 multi-electrode measuring cell whereby the current and voltage characteristics of the electrolyte are measured separately. This enables the electrode surfaces to become coated without impairing operation of the measuring system. With its ability to provide consistently accurate monitoring and control, under conditions which would adversely affect a standard two-electrode conductivity system, the multi-electrode system can be used in areas that would be otherwise maintenance-intensive.
  • Annular carbon for widest application coverage from process waters to caustic and acidic detergents
  • Enables measurements up to 400 mS/cm
  • Guaranteed 1.0 cell constants - no need to calibrate
  • Direct contact temperature sensor provides essential rapid response in CIP processes
  • Dip-type immersion sensor with integral mounting bracket
  • Maximum temperature 100 °C (212 °F)
  • Integral 4.6 m (15 ft) cable


Conductivity Cell 2241

The Conductivity Cell 2241 is a flow-through cell designed for installation in sample lines in paper & pulp manufacture, industrial effluent, water quality monitoring in tidal rivers, river & canal waters, brewing & dairy CIP plants and desalination plants.The associated conductivity instrument utilizes a 2241 multi-electrode measuring cell whereby the current and voltage characteristics of the electrolyte are measured separately. This enables the electrode surfaces to become coated without impairing operation of the measuring system. With its ability to provide consistently accurate monitoring and control, under conditions which would adversely affect a standard two-electrode conductivity system, the multi-electrode system can be used in areas which would be otherwise maintenance-intensive.
  • Annular carbon for widest application coverage from process waters to caustic and acidic detergents
  • Enables measurements up to 400 mS/cm
  • Guaranteed 1.0 cell constants - no need to calibrate
  • Direct contact temperature sensor provides essential rapid response in CIP processes
  • Flow-through sensor with 1/2 in. BSP or NPT threads
  • Maximum temperature 100 °C (212 °F)
  • Maximum pressure 6.6 bar (100 psi)
  • Integral 4.6 m (15 ft) cable

Conductivity Cell 2271

The Conductivity Cell 2271 is designed to be clamped or screwed into pipelines and vessels and is ideal for use in a wide range of applications including brewing & dairy CIP plants, pulp & paper manufacture, industrial effluent and water quality monitoring in tidal rivers, river and canal waters & desalination plants. The associated conductivity analyzer, when connected to the 2271, measures the current and voltage characteristics of the electrolyte separately. This allows the electrode surfaces to become coated without impairing operation of the measuring system. With its ability to provide consistently accurate monitoring and control, under conditions which would adversely affect a standard two-electrode conductivity system, the multi-electrode system can be used in areas which would otherwise be maintenance-intensive.
  • Annular carbon for widest application coverage from process waters to caustic and acidic detergents
  • Enables measurements up to 400 mS/cm
  • Guaranteed 1.0 cell constants - no need to calibrate
  • Direct contact temperature sensor provides essential rapid response in CIP processes
  • Screw-in insertion sensor with 1 in. BSP or NPT threads
  • DIN 11851 Dairy fitting and 2 in. Tri-Clamp for Food & Beverage applications
  • Maximum temperature 100 °C (212 °F)
  • Maximum pressure 6.6 bar (100 psi)
  • Integral 4.6 m (15 ft) cable

聯(lián)系方式

廣州宇林自動(dòng)化控制設(shè)備有限公司

聯(lián)系人:
林立
手機(jī):
13360550980
傳真:
86-020-38897067
類型:
工廠
地址:
石基城市花園商鋪C3-6號(hào)

服務(wù)熱線

86-020-38897067

提示:您在維庫儀器儀表網(wǎng)上采購商品屬于商業(yè)貿(mào)易行為。以上所展示的信息由賣家自行提供,內(nèi)容的真實(shí)性、準(zhǔn)確性和合法性由發(fā)布賣家負(fù)責(zé),請(qǐng)意識(shí)到互聯(lián)網(wǎng)交易中的風(fēng)險(xiǎn)是客觀存在的。 請(qǐng)廣大采購商認(rèn)準(zhǔn)帶有維庫儀器儀表網(wǎng)認(rèn)證的(金牌會(huì)員、VIP會(huì)員、至尊VIP會(huì)員、百維通)供應(yīng)商進(jìn)行采購!