產(chǎn)品描述:
2.1.1輸入電壓Input Voltage
表格1:列舉AC輸入電壓范圍,在此電壓范圍內(nèi),電源應(yīng)正常工作并合電氣性能要求。
Table 1: Lists the AC input operating voltage range. The power shall work rmally and meet all electrical requirements throughout this range.
表格1:AC輸入電壓限值 Table 1: AC Input Voltage Limitations
小值Minimum | 額定值minal | 值Maximum |
100Vac | 110Vac/220Vac | 240Vac |
2.1.2輸入頻率Input Frequency
表格2:列舉AC輸入頻率范圍,在此頻率范圍內(nèi),電源應(yīng)正常工作并合電氣性能要求。
Table 2: List the AC input operating frequency range. The power shall work rmally and meet all electrical requirements throughout this range.
Table 2: AC Input Frequency Limitations AC輸入頻率限值
小值Minimum | 額定值minal | 值Maximum |
47Hz | 50Hz/60Hz | 63Hz |
2.1.3沖擊電流Inrush Current
沖擊電流峰值在額定電壓輸入,冷啟動(dòng)(25℃)時(shí),不大于80A;且在任何負(fù)載和輸入條件下,不導(dǎo)致性損壞或危險(xiǎn),輸入電壓的定義見表格1.
Peak inrush current shall be limited to 80A of rated input voltage and cold start at 25 degre C, and shall t rult in a permanent damage of the power supply under any conditions of load and input voltage as specified at any input voltage as specified in table 1.
2.1.4待機(jī)功耗Standby Input Power
在額定電壓輸入情況下,待機(jī)功耗不大于1W。
The standby input power should more than 1W under the rated input voltage condition.
2.1.5輸入電流Input Current Limiting
在輸入電壓小值,負(fù)載為滿載條件下,輸入電流不大于1.2A。
The input current should be ls than1.2A, under minimum AC input and full load.
2.1.6效率Efficiency
在額定輸入電壓,負(fù)載和額定負(fù)載條件下,電源的效率大于80%.
The power supply efficiency shall be greater than80% under rated input voltage. It will be measured at the tical load and maximum load.
2.2輸出規(guī)格Output Specification
2.2.1電壓調(diào)整率DC Voltage Regulation
在輸出端子量測(cè)的電壓需合表格3中標(biāo)示的調(diào)整范圍。
電壓調(diào)整的限值不包括2.2.4節(jié)中要求的DC負(fù)載瞬態(tài)變化。
The DC output voltag will remain within the regulation rang shown in Table 5 when measured ate the load end of the output connectors.
The voltage regulation limits do t include the transient DC load chang, which are covered in Section 3.2.4.
表格3:輸出電壓調(diào)整限值 Table 3: DC Output voltage regulation limits
Parameter 參數(shù) | Line Regulation 線性調(diào)整 | Load regulation 負(fù)載調(diào)整 | Cross regulation 交叉調(diào)整 |
V1:12V | &plun;5.0% | &plun;10.0% | N/A |
2.2.2輸出電流DC Output Current
表格4:輸出電流限值 Table4: DC output current limits
Parameter參數(shù) | Min Current 小電流 | Rate Current 標(biāo)稱電流 | Max Current 電流 | Unit單位 |
V1:12V | 0 | 5.0 | 5.5 | A |
2.2.3輸出紋波與噪聲Output Ripple and ise
下面表格5是紋波與噪聲要求,以2.2.2節(jié)中定義的負(fù)載范圍和2.1.1節(jié)定義的輸入電壓為測(cè)試條件,紋波與噪聲均應(yīng)合要求,測(cè)試時(shí)示波器設(shè)置為20MHz帶寬,輸出端并接一0.1uF瓷片電容和一10uF鉭電解電容(低R值)。
The following table 5 is output ripple and ise requirements, it will be met throughout the load rang specified in Section 2.2.2 and under all input voltage conditions as specified Section 2.1.1, Measurements will be made with an oscilloscope set to 20MHz bandwidth limit. The outputs will be bed with one 0.1uF multilayer (te X7R) and one 10uF tantalum electrolytic (low R) capacitors.
表格5:紋波與噪聲限值 Table 5: Output rippl and ise limits
參數(shù)Parameter | 值Max. |
V1:12V | 200mVp-p@25 degre C |
2.2.4輸出動(dòng)態(tài)負(fù)載響應(yīng)Output Dynamic Load Rponse
輸出電壓在下列表格6定義的負(fù)載變化時(shí),合規(guī)格要求,負(fù)載變化率為0.1Amps/uS, 50Hz~10 KHz之間。
The output voltag will remain within specified regulation limit of the minal set voltage for chang in load as specified below under the following load steps defined below table 8. At a slew rate of 0.1Amps/uS between 50Hz to 10 KHz.
表格6:輸出動(dòng)態(tài)負(fù)載響應(yīng)限值 Table6: Output dynamic load rponse limits
Dynamic Load 動(dòng)態(tài)負(fù)載 | DC Voltage Regulation 電壓調(diào)整率 |
50%~100%~50% | &plun;10% |
2.2.5電壓過(guò)沖Overshoot at turn-on/ turn-off
開機(jī)或關(guān)機(jī)時(shí),電壓過(guò)沖不得過(guò)標(biāo)稱值的10%.
Any overshoot at turn on or turn off shall be ls than 10% of rated output voltage.
2.3保護(hù)功能Protection Function
2.3.1過(guò)壓保護(hù)Over Voltage Protection(NA)
電源提供過(guò)壓保護(hù). The power supply will provide OVP function.
2.3.2短路保護(hù)Short Circuit Protection
輸出的短路定義為其輸出阻小于0.1歐姆,在上述3.1節(jié)中定義的輸入條件下,電源將進(jìn)行保護(hù),保護(hù)過(guò)程中,不會(huì)出現(xiàn)諸如元器件、連接器等損壞危險(xiǎn)。
An output short circuit is defined as any output impedance of ls than 0.1 ohms. The power supply will protect without damage to overseers of to the unit (components, connectors, etc) under the input conditions specified in Section 3.1 above.
2.3.3過(guò)流保護(hù)Over Current Protection
電源過(guò)流點(diǎn)合下表限值要求,而且過(guò)流保護(hù)危險(xiǎn)和損壞,在保護(hù)去除后,電源自動(dòng)恢復(fù).
The power supply shall meet the limitation requirement as below table without any damage, the unit shall recover and function automatically after the protection is removed.
表格7:過(guò)流保護(hù)限值 Table 7: Over Current Protection limits
參數(shù)Parameter | 小Min. | - | 值Max | 單位Unit |
V1:12V | 4.8 | - | 6.5 | A |
應(yīng)用范圍:
便攜式設(shè)備,安設(shè)備,上網(wǎng)本,顯示器,筆記本電腦,設(shè)備,LED燈驅(qū)動(dòng)等