精品人妻少妇嫩草AV无码专区_69堂亚洲国产日韩精品无码专区成人妻中文字幕一区二区三区在线久久久久_久久久久国产精品

您好,歡迎來(lái)到維庫(kù)儀器儀表網(wǎng) 網(wǎng)站登錄 | 免費(fèi)注冊(cè) | 忘記密碼

咨詢電話SERVICE LINE

86-027-88412886

15927601691

商鋪首頁(yè) 公司介紹 公司動(dòng)態(tài) 產(chǎn)品中心 技術(shù)資料 在線留言 聯(lián)系我們
您所在的位置:維庫(kù)儀器儀表網(wǎng) > 其它測(cè)定儀 > 武漢艾爾通電氣有限公司 > 產(chǎn)品中心 > AL101 Transforme Test System
AL101 Transforme Test System
AL101 Transforme Test System
  • AL101 Transforme Test System
掃一掃

掃一掃
進(jìn)入手機(jī)店鋪

AL101 Transforme Test System

產(chǎn)品價(jià)格:
電議
產(chǎn)品型號(hào):
供應(yīng)商等級(jí):
企業(yè)未認(rèn)證
經(jīng)營(yíng)模式:
工廠
企業(yè)名稱:
武漢艾爾通電氣有限公司
所屬地區(qū):
發(fā)布時(shí)間:
2013/6/21 15:39:15

86-027-88412886       15927601691

吳經(jīng)理(聯(lián)系我時(shí),請(qǐng)說(shuō)明是在維庫(kù)儀器儀表網(wǎng)看到的,謝謝)

企業(yè)檔案

武漢艾爾通電氣有限公司

企業(yè)未認(rèn)證營(yíng)業(yè)執(zhí)照未上傳

經(jīng)營(yíng)模式:工廠

主營(yíng)產(chǎn)品:高壓試驗(yàn)測(cè)試儀

產(chǎn)品搜索

手機(jī)訪問(wèn)

掃一掃
進(jìn)入手機(jī)店鋪

類型:
其它

AL101 Transformer Intelligent Comprehensive Test System Implementation of standards. GB 1094.5-2003 、GB/T 6451-200 1. System function System adopts PLC to auto control and finish test procedure, along with monitoring of upper machine. Upper IPC adopts friendly imaging man-machine interface, with which procedure and condition of test can be visually monitored, and control operation be done directly. Test database is added to upper machine software, enabling the auto save of test data, and generating of real-time test report. System adopts RS485 communication, stable and reliable, with strong anti-interference ability. Wide range of application, full function, suitable for test and measurement of various kinds of transformer. Real time display of test volume, and display of its stable curve. Test of comprehensive performance of transformer can be finished when wire once. Real time save and print of test result, and test data for processing and analysis in future. Test report and data are transmitted to storage medium through floppy drive, USB port and network port. Multi-data display of real time parameter of transformer test, distribution service data from calculation analysis and data curve of time interval, with supervision center monitoring the state of entire transformer test. Historical data recording and superior data query: save of overall historical data of transformer test for operator to analyze running and forecast trend, etc.; capable of quick query and retrieval of real time test data of comprehensive performance and historical data. Capable of software update on basis of original test system. Our self-manufactured high performance testers are installed in the control cabinet, each having a high measuring accuracy.
2. Our self-manufactured high performance testers are installed in the control cabinet: (1) No-load and load tester Function: measuring of loss in no-load and load test of transformer (double- table method, three-table method), and of power factor, average value of voltage, and effective value of current and voltage. To measure and calculate no-load current, and no-load loss after waveform is rectified. Loaded impedance voltage, impedance voltage and loss when rectified to temperature of 75℃ and 120℃ Measuring of frequency of power system voltage Technical index: (when not connected with mutual inductor outside) Measuring range: Voltage measuring range: 0V500V
Current measuring range: 0A~
5A
Power measuring range: 0W~2500W, when at COSφ=0.1~
1
Frequency measuring range: 45Hz~65Hz
Error range: Voltage: 0V~50V,±0.2%Fs;50V~500V, relative error ≤±0.2%
Current: 0A~1A ,±0.2%Fs;1A~
5A, relative error ≤±0.2%
Power: 0W~
2500W, relative error ≤±0.3%Fs.
Frequency: ≤0.5Hz. absolute error within full-scale range
Measuring range of equipment can be expanded by the external connection with mutual inductor
(2)Transformation ratio tester Function: Auto zero position calibration guarantees an optimum behavior for equipment all along. Auto gain calibration, with which user can self-correct accuracy of equipment. High accuracy: range of transformation ratio 1~10000 0.1grade Capable of measuring the transformation ratio of various groups of transformer △/Y、Y/△、Y/Y、△/△、Y/Z、Z/Y、△/Z、Z/△. Technical index: (when not connected with mutual inductor outside) Measuring range of transformation ratio: 1.0000~9999.9 Accuracy: 0.1grade Group measuring range: 00~11(00 stands for 12) Working environment: Input voltage: AC 220±22V 50Hz±1Hz
Temperature: -10~55℃
Humidity: <85%RH
(3) (3) DC resistance tester Function: FK-Ⅳ transformer DC resistance tester, which is easy to operate, accurate in measurement, safe and reliable, has strong anti-interference ability and quick test speed, is a perfect choice for measuring coil resistance of power transformer. Current test: DC constant current: 0.1A、1A、2A Test range:: 0.1A、1A、2A Test range: 0.1A 20Ω—199.99Ω
1A : 5Ω—19.99Ω
2A : 2mΩ—4.999Ω 2A : 2mΩ—4.999Ω resolution: 1 uΩ accuracy: 0.2grade
   

聯(lián)系方式

武漢艾爾通電氣有限公司

聯(lián)系人:
吳經(jīng)理
手機(jī):
15927601691
傳真:
86-027-0000000
類型:
工廠
地址:
中國(guó).湖北省.武漢市

服務(wù)熱線

86-027-88412886

提示:您在維庫(kù)儀器儀表網(wǎng)上采購(gòu)商品屬于商業(yè)貿(mào)易行為。以上所展示的信息由賣家自行提供,內(nèi)容的真實(shí)性、準(zhǔn)確性和合法性由發(fā)布賣家負(fù)責(zé),請(qǐng)意識(shí)到互聯(lián)網(wǎng)交易中的風(fēng)險(xiǎn)是客觀存在的。 請(qǐng)廣大采購(gòu)商認(rèn)準(zhǔn)帶有維庫(kù)儀器儀表網(wǎng)認(rèn)證的(金牌會(huì)員、VIP會(huì)員、至尊VIP會(huì)員、百維通)供應(yīng)商進(jìn)行采購(gòu)!
個(gè)人中心
商家電話

人工服務(wù)電話
86-027-88412886

頂部
立即詢價(jià)
手機(jī)訪問(wèn)

掃一掃
進(jìn)入手機(jī)店鋪