英國(guó)TTi PL-P系列可編程穩(wěn)壓電源 PL155P PL303P PL303QMD-P
PL-P系列是TTI新的線性穩(wěn)壓電源系列可編程產(chǎn)品。有手動(dòng)控制的功能,但增加了全面的遠(yuǎn)程控制功能。
超緊湊型架模塊尺寸非常適合安裝在機(jī)架上的測(cè)試系統(tǒng),而保留臺(tái)式應(yīng)用的手動(dòng)控制程序。
為了滿(mǎn)足今天的工程師們的不同需求,提供一系列的接口。RS-232接口,USB和LAN(以太網(wǎng))與LXI支持提供標(biāo)準(zhǔn)。
每個(gè)數(shù)字總線接口提供的電壓,電流控制,輸出開(kāi)/關(guān),加回讀電壓,電流和地位。
產(chǎn)品特點(diǎn):
- 高性能的線性穩(wěn)壓電源
- 全數(shù)字化遠(yuǎn)程控制和讀出
- RS-232接口,USB和LAN(以太網(wǎng))
- LAN接口符合LXI標(biāo)準(zhǔn)
- 接口的光電隔離輸出
- IVI驅(qū)動(dòng)器提供
- V模擬遠(yuǎn)程控制和我(非隔離)
- 簡(jiǎn)單的主從式并行布線模擬輸出
- 季度架3U超緊湊的尺寸
- 高功率密度達(dá)90瓦特輸出
- 寬范圍的單和雙輸出模型;
- 按新的PL系列手動(dòng)控制功能
產(chǎn)品型號(hào)/規(guī)格:
- PL155-P - 0 to 15V at 0 to 5A
- PL303-P - 0 to 30V at 0 to 3A
- PL601-P - 0 to 60V at 0 to 1.5A
- PL303QMD-P - 2 x (0 to 30V at 0 to 3A)
Digital Bus Interfaces - RS-232, USB, LAN (LXI)
Full remote control and read-back using RS-232, USB or LAN (LXI-C). All interfaces are at ground potential and opto-isolated from the outputs.
Note: Remote/Local Sense, and Operational Mode (PL303QMD-P) are manually selectable only.
RS-232
Standard 9-pin D connector. Baud rate 19,200 max.
USB
Standard USB hardware connection. Operates as a virtual COM port.
Ethernet (LAN)
Standard 10/100 base-T hardware connection. ICMP and TCP/IP Protocol for connection to Local Area Network or direct connection to a single PC.
LXI Compliance
LAN interface is compliant with LXI-C. (LXI is the abbreviation for Lan eXtensions for Instrumentation).
GPIB (only with option G)
Conforms with IEEE-488.1 and IEEE-488.2.
Digital Programming Performance
Voltage Setting
Setting Resolution: 1mV
Setting Accuracy: +/- (0.05% +10mV)
Current Setting
Setting Resolution: 0.1mA (0.01mA on 500mA range)
Setting Accuracy: +/- (0.3% +0.005A) to 3A, +/- (0.5% +0.005A) to 6A, +/- (0.3% +0.5mA) on 500mA range.
Programming Speed
Command Delay: Typically <80ms (this must be added to any of the figures below)
Voltage Up Time: Typically <45ms* to 1%
Voltage Down Time: Typically <20ms* to 1% (full load); typically <150ms* to 1% (no load)
* The up and down times vary with model, current range and voltage step size. More information is contained in the operating manual which can be downloaded from our web site.
Analog Remote Control (single output models only)
Non-isolated analog voltage control of voltage and current. Analog control outputs are also provided to enable easy parallel connection of multiple units in a master-slave configuration.
Note that the PL303QMD-P does not have analog remote control.
Scaling
Reference Point: All control voltage are referenced to the positive output terminal
Set Voltage Input: 0V to 10V sets 0 to 100% of rated output (e.g. 0 to 30V for PL303-P).
Alternative scaling of 0V to 5V (selectable using internal link).
Set Current Input: 0V to 10V sets 0 to 100% of rated output (e.g. 0 to 3A for PL303-P).
Alternative scaling of 0V to 5V (selectable using internal link).
Voltage Output: 0 to 100% of rated output voltage generates 0V to 5V.
Current Output: 0 to 100% of rated output current generates 0V to 5V.
Accuracy
Set Voltage Input: +/- (0.3% +10mV); Input Impedance = 100kOhm
Set Current Input: +/- (0.5% +0.005A); +/- (0.5% +0.5mA) on 500mA range
Input Impedance = 64kOhm
Voltage Output: +/- (0.3% +10mV); Output Impedance = 125Ohm
Current Output: +/- (0.5% +0.005A); +/- (0.5% +0.5mA) on 500mA range; Output Impedance = 125Ohm
Remote Analog On/Off Control (single output models only)
Non-isolated terminal which sets the output to Off when pulled low by gate signal or relay closure. Signal is reference to the positive output terminal.
Note that the PL303QMD-P does not have this facility.
Rear Terminals
Power and sense connections are duplicated on the rear panel using a screw-less connector block.
Digital Bus Interfaces - RS-232, USB, LAN (LXI)
NOTE: The above specifications are additional to the Manual Control specifications which can be seen Here.
GENERAL SPECIFICATIONS
Input
AC Input: 230V AC or 115V AC +/- 10%, 50/60Hz. Installation Category II
Input Power: Single output models - 280VA max.; Dual output models - 560VA max.
Temperature & Environmental
Operating Range: +5oC to +40oC, 20% to 80% RH
Storage Range: -40oC to + 70oC
Environmental: Indoor use at altitudes up to 2000m, Pollution Degree 2.
Cooling: Intelligent variable-speed low noise fan assists convection.
Safety & EMC
Safety: Complies with EN61010-1
EMC: Complies with EN61326
Physical
Size: Single output models - 107mm x 131mm (1/4 rack 3U) x 343mm,
Dual output models - 214mm x 131mm (1/2 rack 3U) x 288mm
Triple output models - 321mm x 131mm (3/4 rack 3U) x 288mm
(sizes exclude feet, knobs and terminals).
Weight: Single output models - 4.55kg (10lb);
Dual output models - 9.05kg (19.9lb)
Triple outpuut models - 13.0kg (28.6ib)
DRIVER SOFTWARE SUPPLIED
IVI Driver
An IVI driver for Windows is supplied. This provides support for common applications such as LabView*, LabWindows*, HPVEE* etc.
USB Driver
An installation file is supplied which calls a standard Windows* USB driver.
* LabView and LabWindows are trademarks of National Instruments. HPVEE (now Agilent VEE) is a trademark of Agilent Technologies. * USB interface is supported for Windows 98-SE, 2000, XP, and Vista. Windows is a trademark of Microsoft.
OPTIONS
Rack Mount (RM450)
19 inch 4U rack mount suitable for up to four single power supplies, two dual power supplies, or any mixture. Blanking plates are provided for unused positions. The 4U height provides limited ventilation space above and below the power supplies.
GPIB Interface (Option G)
GPIB (IEEE-488) interface fitted in addition to other interfaces.